Send e-mail to electway@yahoo.com for more details Visit our on-line store
Specification Selectsion Guide
Three phrase Input-three phrase output |
|||||||
Rating capacity (VA) |
10KVA |
15KVA |
20KVA |
30KVA |
40KVA |
60KVA |
80KVA |
Rating power (W) |
9KW |
13.5KW |
18KW |
27KW |
36KW |
54KW |
72KW |
Input |
|||||||
Input valtage range |
380/400/415Vac±15%, three phase input |
||||||
Input frequency range |
50/60 ±5HZ automatically indentify |
||||||
Power factor |
>0.8(without filter),can achieve unit power factor(have filter) |
||||||
Output |
|||||||
Rating output current |
15A |
23A |
30A |
45A |
60A |
90A |
120A |
Rating output voltage |
380/400/415Vac±1% |
||||||
Output frequency |
Automatically tack the input |
||||||
Output waveform |
Sine wave |
||||||
Frequency range |
50/60 ±0.05%HZ |
||||||
Power factor |
0.9(lag) |
||||||
Distortion |
Linear load<3%,No-linear load<5% |
||||||
Over load capability |
over load to 110%,125%,150%, can keep working 60min/10min/1min |
||||||
Peak factor |
3:1 |
||||||
Overall efficiency |
88% |
89% |
89% |
90% |
90% |
91% |
91% |
Convertion time |
|||||||
Main supply->BAT |
0ms |
||||||
Bypass |
|||||||
Rating voltage |
380/400/415VAC |
||||||
Voltage range |
UP +15%,DOWN -20% |
||||||
Rating frequency |
50/60 Hz automatically indentify |
||||||
Frequency range |
±2% |
||||||
Convert time |
0ms/1ms |
||||||
Over load capability |
15 times rating current (10ms), 5times rating current (5s) |
||||||
Battery |
|||||||
Battery voltage(VDC) |
320—490VDC:380VAC,30 cells batteries;400 VDC,31 cells batteries;410VDC 32 cells batteries |
||||||
Panel display |
|||||||
LED |
Indicate the input,,inverter,bypass,battery and output status |
||||||
LCD |
Display the input/output voltage,frequency,power,power factor;battery Voltage,current,status;Load status,UPS status,history data,seting paramater |
||||||
Communication |
|||||||
Communication interface |
Dry contact,RS232,RS485,SNMP card |
||||||
Working enviroment |
|||||||
Working temperature |
0~40℃ |
||||||
Working humidity |
0~95% no condensation |
||||||
Restore temperature |
-25 ℃~55℃ |
||||||
Noise(range in 1M) |
<63dB |
<67dB |
|||||
Options Harmonic filter,Snmp adapter,Bapass current-inductance |
|||||||
Standard: YD/T1095 |
Production description Introduction
EP series power frequency-line UPS uses smart chip which have dual-DSP control, advanced control technology and double conversion topology flutter architecture eliminatie the interference from various kinds of power network.
UPS's output electrical power is some regulated voltage, without noise and interference from power fluctuations, low distortion of pure sine wave.this power has
strong load capacity, good load compatibility and wide utility input voltage and frequency range and it also has excellent compatibility matching the generator output
without switching time, etc., UPS's output electrical power is great to meet the needs of a variety of application environments.
Comprehensive protection system of the EP UPS improve system stability, reliability; comprehensive supervision capabilities, support RS232 and RS485,
Largescreen LCD display, support Chinese and English operation menu. Monitoring components completely monitor the UPS status,working order ,fault event's
and working history. Intelligent battery management functions can automatically convert the charging mode, predict the battery discharge time,
periodic do self-test battery to improve battery life and can be adapted to advanced network systems.
★ Power range:10KVA-80KVA ,can parallel machines, and machine number can up to four
★ Working mode: smart power frequency on line (three input-three output)
★ Application:workstations, large network servers, computer rooms and data centers
Share on: