3-phase in / 1-phase out Visit our on-line store
On-line double conversion technology
Static switch bypass
Manual Maintenance bypass
CPU control
Multi-function LCD and LED front panel
Remote monitoring and control management
Remote notify
Redundant architecture design
Expandable back-up time capability
Auto diagnostics, alarm
Low audible noise level
Complete power protection by an on-line double conversion design incorporating an automatic static bypass from overload and fault conditions.
Low running costs with a high operating efficiency. SENDON GENIUS UPS uses IGBT(insulated gate bipolar transistor) technology in the inverter to achieve its high efficiency.
Wide input voltage range to minimize chances of battery cutting in and extend battery life.
CPU control, easy to monitor and control all functions of the UPS including operation,battery management, automatic restart and shutdown, and provide real time mains-and load readings.
High reliability and low maintenance. SENDON GENIUS UPS has a built in manual maintenance bypass, MTBF (mean time between failure) more than 200,000 hours, and MTTR(mean time to repair) less than 15 minutes.
High level remote monitoring and control via Port RS232 . According with TCP/IP 、SNMP. Sending remote notify by e-mail, pager or mobile phone. Clear front panel with LCD and LED provide real time information of UPS operation status.
By using sophisticated logic cortrol system. SENDON PIONEER ups provide hight reliability transfer redundant system and up to eight-unit parallel system.
3-phase input/1-phase output .It is not necessary to consider the load balance, easy to use.
MODELS
|
1006
|
1010
|
1015
|
1020
|
1030
|
1040
|
1060
|
|||||||||||||
Power(CosФ=0.8)(KVA)
|
6
|
10
|
15
|
20
|
30
|
40
|
60
|
|||||||||||||
INPUT
|
||||||||||||||||||||
Nominal Volt.
|
380V±25%( 3 phase 4 wires)
|
|||||||||||||||||||
Frequency
|
50Hz±10%
|
|||||||||||||||||||
INVERTER OUTPUT
|
||||||||||||||||||||
Phase
|
1phase
|
|||||||||||||||||||
Nominal Volt.
|
220V
|
|||||||||||||||||||
Crest Factor
|
3:1
|
|||||||||||||||||||
Wave Form
|
sine wave
|
|||||||||||||||||||
THD
|
3%
|
|||||||||||||||||||
Volt. Stability
|
±1%
|
|||||||||||||||||||
Volt. Transient Response
|
±5%(0-100% Load step)
|
|||||||||||||||||||
Frequency
|
The same of input
|
|||||||||||||||||||
Frequency Stability
|
(without synchronization ) 50Hz±0.5%
(with synchronization) 50Hz±2% |
|||||||||||||||||||
Over load
|
120% , 10 min.
150% , 1 min. |
|||||||||||||||||||
BATTERY
|
||||||||||||||||||||
Type
|
Maintenance-free sealed Lead-Acid battery VLAP
|
|||||||||||||||||||
Volt.
|
192V
|
384V
|
||||||||||||||||||
BYPASS SYSTEM
|
||||||||||||||||||||
Configuration
|
static switch+Manual maintenance by pass
|
|||||||||||||||||||
Input Phase
|
1phaes
|
|||||||||||||||||||
Input Volt. Tolerance
|
±15%
|
|||||||||||||||||||
Transfer switch time
|
0(Make before break)
|
|||||||||||||||||||
SYSTEM
|
||||||||||||||||||||
Computer Interface
|
RS232
|
|||||||||||||||||||
Operating Temperature
|
0-40℃
|
|||||||||||||||||||
Relative Humidity
|
95% (Non-condensing)
|
|||||||||||||||||||
Operating Altitude
|
1000m at rated power(-1% for each 100m over 1000m) – max. 4000m
|
|||||||||||||||||||
Noise at 1 m(dB)
|
<50dB
|
|||||||||||||||||||
Standards
|
UL、CE surge voltage PROTECTION reach 1000V, Suppression of electromagnetic disturbance reach the class A level of FCC
|
|||||||||||||||||||
Dimension (D*W*H)mm
|
675*330*970
|
680*375*970
|
680*580*970
|
700*560*1220
|
||||||||||||||||
Weight (Kg)
|
112
|
128
|
178
|
200
|
300
|
380
|
510
|
Model |
6KVA |
10KVA |
15KVA |
20 KVA |
30 KVA |
40 KVA |
50 KVA |
60 KVA |
80 KVA |
100KVA |
120 KVA |
Capacity (KVA) |
5 |
10 |
15 |
20 |
30 |
40 |
50 |
60 |
80 |
100 |
120 |
Input single max. current |
10 |
19 |
28 |
38 |
57 |
76 |
86 |
102 |
133 |
164 |
195 |
Working way and principle |
On line,static bypass switch (zero transfer time ), Double switch technology, output power to totally isolate |
||||||||||
Phase |
3phase +N+G |
||||||||||
Nominal voltage |
400VAC±25% |
||||||||||
Nominal frequency |
50Hz±10%,60Hz±10% |
||||||||||
Voltage harmonics distortion |
<10% |
||||||||||
Soft start |
0~100% 5sec |
7.1.2. Rectifier output parameter; Please refer to the following table 3
Table 3
Model |
6 KVA |
10 KVA |
15 KVA |
20 KVA |
30 KVA |
40 KVA |
50 KVA |
60 KVA |
80 KVA |
100 KVA |
120 KVA |
Max. output voltage |
405VDC |
||||||||||
Microcomputer setting charge current |
3A~30A(depend on battery capacity) |
7.2 Battery Please refer to the following table 4
Table 4
Model |
6 KVA |
10 KVA |
15 KVA |
20 KVA |
30 KVA |
40 KVA |
50 KVA |
60 KVA |
80 KVA |
100 KVA |
120 KVA |
Max.discharge current(A) |
19 |
28 |
42 |
56 |
85 |
113 |
141 |
169 |
225 |
282 |
338 |
Battery quantity |
30pcs |
||||||||||
Nominal battery voltage |
360VDC |
||||||||||
Floating voltage |
405VDC |
||||||||||
Charge current |
3A~30A(depend on battery capacity) |