High Reliability
Built-in AC charger and inverter
Fully automatic restart operation
Overvoltage / undervoltage / short circuit / overload / over-temperature/battery poles anti-reverse protection
Mains and inverter switch quickly
Allowed to cut off DC when the power is on, automatically switch to bypass and does not affect the supply to the load for convenient battery maintenance and replacement
High Efficiency, Minimize Charging Loss
Advanced technology to optimize battery life
The battery voltage is too high or too low, the inverter shutdown output and automatic recovery if the battery voltage is back to normal
Load Compatibility
Inverter shutdown output due to overload, after eliminating the overload, inverter will automatically restore the output power
Support power on without DC, you can run only the mains input. This feature allows first put into inverter to use and then install the battery
Cheap, Cost-Effective and Flexible select
DC 12V/24V, AC 220/230/240V output
User-friendly design, easy to install and operate
Different outlet options
Applications
TV, stereo, notebook computer and other home appliances
Cars, electric cars, trains, yachts, ships
The power outage place: homes, offices, stores
Field operations, tourism
Night commercial activities Location: night market, shops, stalls, farms, etc
MODEL(XPR) | 1200VA | 2400VA |
Rated Power | 1200VA/720W | 2400VA/1440W |
BATTERY | ||
Battery | 12Vdc | 24Vdc |
Constant Current Charger Voltage | 14.3Vdc | 28.6Vdc |
Floating Charge Voltage | 13.7Vdc | 27.4Vdc |
Low-battery Alarm Voltage | 10.2Vdc | 20.4Vdc |
Overcharge Protection | 15.0Vdc | 30.0Vdc |
Shutdown Voltage | 9.9Vdc | 19.8Vdc |
Backup Time | The backup time is up to battery capacity | |
INPUT | ||
Phase | L+N | |
Input Voltage | (90-290)Vac | |
Input Frequency | 50/60Hz(Auto detection) | |
OUTPUT | ||
Output Voltage | 220/230/240Vac±10%(settable) | |
Output Frequency | 50/60Hz (Auto Sensing) | |
Output Power Factor | 0.6 | |
Overload Capability |
line mode:110%<load<130, 5min; >130%, shut down; battery mode:110%<load<120, 15s; >120%, shut down; |
|
Transfer Time | 20ms typical | |
Output Waveform | Modified Sine Wave | |
Overload Capability |
100%<Load<130%:show alarm after 5min and go to fault; 130%<Load:shut down immediately and go to fault; |
|
SYSTEM | ||
Efficiency | AC to DC:>95%; DC to DC:>82% | |
Noise (1m front) | <55dBA | |
Operation Temperature | 0°C to +40°C | |
Humidity | 0~90% non-condensing | |
Storage Temperature | -15°C to +50°C | |
Altitude | 1000m | |
Dimension(W×D×H mm) | 231.5×293×82.5 | |